Product Overview
Following are the specifications of Wire (RVS RVV) : 1. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable. 2. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. (BV-90) Heat resistant copper conductor PVC insulated wire at 90 0 C Mainly be laid at the places of high temperature environment and can be laid indoors ,conduits. BVR Copper conductor PVC insulated flexible cable Be for laying permanent place where flexible required. 60227IEC10 (BVV) BVV Copper conductor PVC insulated PVC sheathed round wires Fixed laid, fit for the places with high mechanical protection and moisture place, can be laid in the air or underground. BLVV Aluminum conductor PVC insulated PVC sheathed round wires BVVB Copper conductor PVC insulated PVC sheathed flat wires BLVVB Aluminum conductor PVC insulated PVC sheathed flat wires 60227IEC02(RV) 60227IEC06(RV) Copper conductor PVC insulated flexible connector wire Mainly used at middle and light style moving electronics, home appliances, power and lighting and the places where flexible required.
Following are the specifications of Wire (RVS RVV) : 1. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable. 2. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. (BV-90) Heat resistant copper conductor PVC insulated wire at 90 0 C Mainly be laid at the places of high temperature environment and can be laid indoors ,conduits. BVR Copper conductor PVC insulated flexible cable Be for laying permanent place where flexible required. 60227IEC10 (BVV) BVV Copper conductor PVC insulated PVC sheathed round wires Fixed laid, fit for the places with high mechanical protection and moisture place, can be laid in the air or underground. BLVV Aluminum conductor PVC insulated PVC sheathed round wires BVVB Copper conductor PVC insulated PVC sheathed flat wires BLVVB Aluminum conductor PVC insulated PVC sheathed flat wires 60227IEC02(RV) 60227IEC06(RV) Copper conductor PVC insulated flexible connector wire Mainly used at middle and light style moving electronics, home appliances, power and lighting and the places where flexible required.